Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 往年索引

基于層次分析法的110 kV電網(wǎng)綜合安全風險評估研究

來源:電工電氣發(fā)布時間:2019-08-16 12:16 瀏覽次數(shù):739
基于層次分析法的110 kV電網(wǎng)綜合安全風險評估研究
 
馮大偉1,尹云劍2,王震泉1,管永高1
(1 中國能源建設集團江蘇省電力設計院有限公司,江蘇 南京 211102;
2 國網(wǎng)江蘇省電力有限公司檢修分公司,江蘇 南京 211102)
 
    摘 要:將電網(wǎng)安全風險相關的網(wǎng)絡拓撲結構、負荷、線路載流量等基礎數(shù)據(jù)進行標準化處理,根據(jù)配電網(wǎng)直接面向負荷的特點,建立起基于負荷損失風險的110 kV電網(wǎng)安全風險計算模型,利用層次分析法與雷達圖將風險指標和標準化處理之后的基礎數(shù)據(jù)進行聚合,并通過雷達圖反映指標聚合前后的變化,找出影響電網(wǎng)安全風險的關鍵指標。建立起一套基于110 kV電網(wǎng)基礎數(shù)據(jù)的綜合安全風險評估體系,來反映電網(wǎng)存在的安全風險點,以便于電網(wǎng)運行管理者對影響110 kV電網(wǎng)安全的關鍵指標加以改善。以某地級市電網(wǎng)進行實際測試,結果表明,所述方法能準確反映造成電網(wǎng)安全風險的主要指標,與電網(wǎng)實際運行情況基本相符。
    關鍵詞:110 kV電網(wǎng);安全風險計算模型;層次分析法;基礎數(shù)據(jù)聚合;綜合風險評估體系
    中圖分類號:TM732     文獻標識碼:A     文章編號:1007-3175(2019)08-0021-05
 
Research on Comprehensive 110 kV Power Grid Security Risk Assessment Based on Analytic Hierarchy Process
 
FENG Da-wei1, YIN Yun-jian2, WANG Zhen-quan1, GUAN Yong-gao1
(1 China Energy Engineering Group Jiangsu Power Design Institute Co., Ltd, Nanjing 2111 02, China;
2 State Grid Jiangsu Electric Power Co., Ltd, Maintenance Branch Company, Nanjing 2111 02, China)
 
    Abstract: This paper standardized the basic data related to grid security risk, including the topological structure of power grid, load and current carrying capacity of transmission lines. As distribution systems were directly based on load, an 110 kV power grid security risk calculation model based on load loss risk was established to calculate risk indicators. The analytic hierarchy process (AHP) and radar chart method were used to aggregate the risk indicators and the standardized basic data. Key indicators that affected the power grid security risks could be identified by analyzing the indicators changes before and after the aggregation in the radar chart. This paper established a comprehensive safety risk assessment system based on the basic data of 110 kV power grid to reflect the security risk point existing in power grid, so that the power grid operation administrator could improve the key indicators that affected the 110 kV power grid security. An actual test was carried out on certain city power grid. The results show that the method mentioned above can accurately reflect the main indicators affecting the grid security risks, which is basically consistent with the actual operation of the power grid.
   Key words: 110 kV power grid; security risk calculation model; analytic hierarchy process; essential data aggregate; integrated risk assessment system
 
參考文獻
[1] 萬國成,任震,田翔. 配電網(wǎng)可靠性評估的網(wǎng)絡等值法模型研究[J]. 中國電機工程學報,2003,23(5):48-52.
[2] 張桂玲,尹星光,劉若溪. 城市電網(wǎng)安全性指標分析[J]. 廣東電力,2011,24(7):17-21.
[3] 劉若溪,張建華,吳迪. 基于風險理論的配電網(wǎng)靜態(tài)安全性評估指標研究[J]. 電力系統(tǒng)保護與控制,2011,39(15):89-95.
[4] MC CALLEY J D, FOUAD A A, VITTAL V, et al. A risk-based security index for determining operating limits in stability-limited electric power system[J]. IEEE Transactions on Power Systems,1997,12(3):1210-1219.
[5] 李蕊,李躍,徐浩,等. 基于層次分析法和專家經(jīng)驗的重要電力用戶典型供電模式評估[J]. 電網(wǎng)技術,2014,38(9):2336-2341.
[6] 趙云飛,陳金富. 層次分析法及其在電力系統(tǒng)中的應用[J]. 電力自動化設備,2004,24(9):85-87.
[7] 翁嘉明,劉東,何維國,等. 基于層次分析法的配電網(wǎng)運行方式多目標優(yōu)化[J]. 電力系統(tǒng)自動化,2012,36(4):56-61.
[8] 徐鵬,楊勝春,李峰,等. 基于層次分析和變權重機制的電網(wǎng)安全指標計算及展示方法[J]. 電力系統(tǒng)自動化,2015,39(8):133-140.